FeaturesIntrinsically safe True-RMS AC voltage and current for accurate measurement on non-linear signalsLow pass filter ensures accurate voltage and frequency measurements on variable speed motor drives (VSDs)10000 uF capacitance range for components and motor capsConductance measurements for high resistance or leakage testsMinimum maximum/average and peak capture to record transients and variations automaticallyRelative mode to remove test lead interference on resistance measurements, rubber holster external protectionAuto and manual ranging for maximum flexibilityInput alert protects you by chirping and flashing lead when leads are plugged into the wrong inputsEasy to use6000 count/19999 count in high resolution mode, LCD with backlightResistance range - 0.1 Ohm to 50 MOhm with accuracy of +/-(0.2% 1)Capacitance range 10 nF to 9999 uF with accuracy of +/-(1% 2)Frequency range 0.5 Hz to 199.99 kHz with accuracy of +/-(0.005% 1)400 hr battery lifeIECEx Ex ia IIC T4 Gb, Ex ia IIIC T 130 deg C dB, I M1 Ex ia I Ma